Step
8.
Configure the MLD last
listener query interval.
Configure the MLD other
9.
querier present interval.
Configuring MLD query and response parameters on an interface
Step
1.
Enter system view.
2.
Enter interface view.
Configure the MLD querier's
3.
robustness variable.
4.
Configure the startup query
interval.
5.
Configure the startup query
count.
6.
Configure the MLD query
interval.
7.
Configure the maximum
response delay for MLD
general query messages.
8.
Configure the MLD last
listener query interval.
9.
Configure the MLD other
querier present interval.

Configuring MLD fast-leave processing

In some applications, such as ADSL dial-up networking, only one multicast receiver host is attached to a
port of the MLD querier. To allow fast response to the MLD done messages of the host when it switches
Command
last-listener-query-interval interval
timer other-querier-present
interval
Command
system-view
interface interface-type
interface-number
mld robust-count robust-value
mld startup-query-interval interval
mld startup-query-count value
mld timer query interval
mld max-response-time interval
mld last-listener-query-interval
interval
mld timer other-querier-present
interval
351
Remarks
1 second by default.
By default, the other querier
present interval is determined by
the formula "Other querier present
interval (in seconds) = [ MLD query
interval ] × [ MLD querier's
robustness variable ] + [ maximum
response delay for MLD general
query ] /2".
Remarks
N/A
N/A
2 times by default.
By default, the startup query
interval is 1/4 of the "MLD query
interval".
By default, the startup query count
is the same as the robustness
variable.
125 seconds by default.
10 seconds by default.
1 second by default.
By default, the other querier
present interval is determined by
the formula "Other querier present
interval (in seconds) = [ MLD query
interval ] × [ MLD querier's
robustness variable ] + [ maximum
response delay for MLD general
query ] /2".