Emerson Rosemount 1595 Reference Manual
Emerson Rosemount 1595 Reference Manual

Emerson Rosemount 1595 Reference Manual

Conditioning orifice plate
Hide thumbs Also See for Rosemount 1595:

Advertisement

Reference Manual
00809-0100-4828, Rev EA
November 2007
Rosemount 1595 Conditioning Orifice Plate
www.rosemount.com

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Rosemount 1595

  • Page 1 Reference Manual 00809-0100-4828, Rev EA November 2007 Rosemount 1595 Conditioning Orifice Plate www.rosemount.com...
  • Page 3 The products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate readings. For information on Rosemount nuclear-qualified products, contact your local Emerson Process Management Representative. www.rosemount.com...
  • Page 5: Table Of Contents

    Installation..........2-5 Rosemount 1595 Types: ....... . 2-5 Rosemount 1496 Types: .
  • Page 6 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 TOC-2...
  • Page 7: Using This Manual

    Returning the Product ......page 1-1 USING THIS MANUAL This product manual provides installation, configuration, calibration, troubleshooting, and maintenance instructions for the Rosemount 1595 Conditioning Orifice Plate. Section 2: Installation...
  • Page 8 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007...
  • Page 9: Safety Messages

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Section 2 Installation Safety Messages ....... . . page 2-1 Location and Orientation .
  • Page 10: Location And Orientation

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 LOCATION AND The orifice plate electronics must be installed in the proper orientation relative to the pipe and the fluid measured. ORIENTATION Horizontal Pipe OPERATING TEMPERATURE LIMITS Installation For line sizes 2-in. (50 mm) to 24-in. (600mm) Temperature Range: -320 to 1200°F (-196 to 649°C)
  • Page 11: Vertical Pipe Installation

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Liquid or Steam in Horizontal Pipes The electronics should be mounted below the pipe to ensure that gases do not collect on the transmitter sensing diaphragms. Figure 2-2. Liquid and Steam in...
  • Page 12: 1595 Straight Pipe Requirements

    Butterfly valve (75% to 100% open) Downstream (outlet) side of primary (1) Consult an Emerson Process Management representative if the type of disturance is not listed. (2) Not applicable in line sizes greater than 24-in. (600 mm). Pressure Tap Orientation Orient the 1595 Conditioning Orifice Plate so that the pressure taps are centered between any 2 (of 4) orifice bore holes.
  • Page 13: Installation

    Rosemount 1595U with Plate Holder (PH) NOTE For 1496 Flange Union or 1497 Meter Section installation, refer to the Rosemount 1595 Conditioning Orifice Plate reference manual (document number 00809-0100-4828). Use the following steps to install the 1595 conditioning orifice plate (paddle or universal plate style).
  • Page 14 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Figure 2-5. Rosemount 1595P Installation Stud Pipe Section Jackscrew Plug (2) 1595 Nuts Jackscrew (2) Jackscrew Gasket (2) Transmitter (1) The installation drawings applies when using the Rosemount 3051S, Rosemount 3051C, and Rosemount 3095MV transmitter.
  • Page 15 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 For sizes > 24-in. (600 mm) and use with alignment tool. When an alignment tool is provided, install the alignment tool on the flange studs shown in Figure 2-7. For Horizontal installation, use the horizontal lift hole (stamped HLH on paddle) to lift the conditioning orifice plate from a horizontal position and guide into location between the flanges.
  • Page 16: Rosemount 1496 Types

    Rosemount 1595 November 2007 NOTE To ensure the best possible flow measurement accuracy, Emerson provides an Official DP Calculation Sheet with every 1595 Conditioning Orifice Plate. The Official DP Calculation sheet uses the calibration factor which is unique to that device and is also stamped on the orifice plate. The Official DP...
  • Page 17: Rosemount 1497 Types

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Rosemount 1497 Types: 1497 WN 1497 RJ 1497SO Step 1: Determine the Proper Orientation See “Location and Orientation” on page 2-2. Step 2: Install the Meter Section Follow these steps to weld the orifice flanges to the pipe.
  • Page 18 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 2-10...
  • Page 19 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 2-11...
  • Page 20 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 2-12...
  • Page 21: Specifications

    Ordering Information ......page A-7 SPECIFICATIONS The Rosemount 1595 can be used with Rosemount 1496 Orifice Flange Unions and Rosemount 1497 Meter Sections. For product offering see document number 00813-0100-4792.
  • Page 22: Functional Specifications

    5,000. For pipe Reynold's Numbers less than 10,000 add an additional +0.5% uncertainty to the discharge coefficient uncertainty. Pipe Sizes 2 to 24-in. (50 to 600 mm). Contact Emerson Process Management for other pipe sizes. Operating Limits For line sizes 2-in. (50 mm) to 24-in. (600 mm) Temperature Range: –320 to 1200 °F (–196 to 649 °C)
  • Page 23 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Typical Orifice Hole Sizes Beta is calculated by: (β) = d / Pipe ID, where the calculated bore is equal to 2 x typical orifice hole size (d = 2d). The table below shows the diameter of each of the four typical orifice holes.
  • Page 24: Dimensional Drawings

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 DIMENSIONAL DRAWINGS Rosemount 1595 Conditioning Orifice Plate (ANSI, Paddle, Square edged, Concentric) Paddle Diameter Length Paddle Width Table A-5. Orifice Plate Dimensions in inches (millimeters) Diameter for Paddle Type Line Size...
  • Page 25 8.437-in. (214.3 mm) 10-in. 10.687-in. (271.45 mm) 12-in. 12.593-in. (319.862 mm) NOTE: Consult Factory for availability of line sizes not shown in the above table. Rosemount 1595 Conditioning Orifice Plate (DIN, Paddle, Square edged, Concentric) Paddle Diameter Length Paddle Width Table A-7.
  • Page 26 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Table A-8. A.P.I Ring No.’s and Rating Line Size A.P.I Ring No. Rating (lbs.) Line Size A.P.I Ring No. Rating (lbs.) R-23 300-600 R-49 300-600 & 900 R-24 900-1500 R-50 1500...
  • Page 27: Ordering Information

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 ORDERING INFORMATION Rosemount 1595 Orifice Plate Ordering Table Model Product Description 1595 Conditioning Orifice Plate Code Plate Type Paddle, Square Edged Universal, Square Edge Code Line Size 2-in. (50 mm) 3-in. (76 mm) 4-in.
  • Page 28 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Rosemount 1595 Orifice Plate Ordering Table Code Options Flow Calibration Discharge Coefficient Verification (3 points) Discharge Coefficient Verification (10 points) Plate Holder Plate Holder for Universal Type Orifice Plate for use with RTJ flange or section...
  • Page 29: Installation Drawings

    Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007 Appendix B Installation Drawings Installation Drawings See the appropriate reference manual for 1496 Flange Unions and 1497 Meter sections being used in the assembly. • Rosemount 1495 Orifice Plates (document number 00809-0100-4792)
  • Page 30 Reference Manual 00809-0100-4828, Rev EA Rosemount 1595 November 2007...
  • Page 32 The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners.