7.7.2

Parameter clear

Parameter clear can be performed from the master.
PNU
P2.2
Parameter clear
P2.3
All parameter clear
P2.5
Parameter clear
P2.6
All parameter clear
P2.8
Error history clear
* Communication parameters (Pr. 117 to Pr. 124, Pr. 338 to Pr. 340, Pr. 343, Pr. 349, Pr. 549 to Pr. 551) are not cleared.
7.7.3

Operation mode read/write

Read/write of the operation mode can be performed from the master.
PNU
P3
Operation mode read/write
7.7.4

Set frequency read

The frequency set to the inverter can be read from the master.
PNU
P4.1
Set frequency (RAM) read*
P4.2
Set frequency (EEPROM) read*
* It is always displayed as frequency (Hz) regardless of the Pr. 37 setting.
Item
Item
External operation mode:10H
PU operation mode:11H (Pr.79 = "6")
Network operation mode:14H
Item
Set frequency (RAM) is read.
Set frequency (EEPROM) is read.
PPO TYPE SUPPORT SPECIFICATION
Data Definition
965AH
99AAH
5A96H
AA99H
0000H
Data Definition
Data Definition
Data Type
AUs16
AUs16
AUs16
AUs16
AUs16
Data Type
Us16
Data Type
7
AUs16
AUs16
55