Mitsubishi Electric FR-E720-0.1K Instructions Manual page 29

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

INVERTER SETTING
(3) Operation mode switching method
When "0 or 1" is set in Pr. 340
Switching from the network
Switch to the external
operation mode from
the network.
Network operation
When "10" is set in Pr. 340
Network operation
For the switching method from the external terminal, refer to the inverter manual.
Refer to page 55 and 76 for a switching method from the network.
CAUTION
• When starting the inverter in network operation mode at powering on or an inverter reset, set a value other
than 0 in Pr. 340. (Refer to page 20)
• When setting a value other than 0 in Pr. 340, make sure that the initial settings of the inverter are correct.
22
External operation
Switch to network operation
mode from the network.
Press
of the PU to light
Press
of the PU to light
Switching from the PU
Press
of
the PU to light
Press
of
the PU to light
PU operation
PU operation