Mitsubishi Electric FR-E720-0.1K Instructions Manual page 55

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

PPO TYPE SUPPORT SPECIFICATION
(2) PZD
Name
Control enable
Fault reset
(Reset)
PZD enable
STW
Forward rotation
command (STF signal)
Reverse rotation
command (STR signal)
Second function
selection (RT signal)
Output stop
(MRS signal)
RAM/EEPROM
48
Bit
0 to 2
Not used (1 is set)
0: Inverter output shutoff
3
1: Inverter output shutoff is cancelled
4 to 6
Not used (1 is set)
[At inverter error]
0: No action
1: When Pr. 349 = "0", error reset can be made in any operation mode.
7
When Pr. 349 = "1", error reset is enabled only in NET operation mode.
[When inverter is normal]
No action
8, 9
Not used (0 is set)
0: Command request of PZD is not processed. (Note that PZD enable and
command count request can be executed.)
10
1: Command request of PZD is processed.
*
At power-on or inverter reset, set 1 once.
0: OFF (Stop command)
11
1: ON (Forward rotation start)
0: OFF (Stop command)
12
1: ON (Reverse rotation start)
0: OFF
13
1: ON (Second function is selected)
0: OFF
14
1: ON (output is shut off)
0: Set frequency (HSW) is written to RAM (Power-on reset returns the
15
changed set frequency to the setting before it was written to RAM.).
1: Set frequency (HSW) is written to EEPROM.
Definition
A starting command is input to the
inverter when the signal turns on.
A stop command is given when both
signals turn on simultaneously.