Mitsubishi Electric FR-E720-0.1K Instructions Manual page 83

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

PPO TYPE NON SUPPORT SPECIFICATION
(3) Operation mode write
Write of the operation mode can be performed from the master.
IND
PNU
0100H
BH
(4) Set frequency read/write
The frequency set to the inverter can be read/written from the master.
IND
PNU
0100H
DH
0100H
EH
*1
Writing to PNU = DH or PNU = EH can be read out from PNU = DH.
*2
To change the running frequency consecutively, always write data to the inverter RAM.
(5) Terminal input read
The analog input values of terminal 2, 4 can be read.
IND
PNU
0100H
FH
Terminal 2 input value read
0100H
10H
Terminal 4 input value read
76
Item
Operation mode
Item
Set frequency (RAM)
*1
Set frequency (EEPROM)
Name
External operation mode:10H
PU operation mode:11H (When Pr.79 = "6")
Network operation mode:14H
Set frequency (RAM) is read or written.
Write set frequency to EEPROM.
*1,2
Minimum
Setting
Increments
0.1%
0.1%
Data Definition
Data Definition