Mitsubishi Electric FR-E720-0.1K Instructions Manual page 77

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

PPO TYPE NON SUPPORT SPECIFICATION
(2) PZD
Name
Inverter running
(RUN signal)
Forward running
Reverse running
Up to frequency
(SU signal)
ZSW
Overload alarm
(OL signal)
Output frequency
detection
(FU signal)
Fault output
(ALM signal)
HIW
70
Bit
0 : OFF
0
1 : ON (inverter running)
0 : Other than forward running
1
(during stop or reverse rotation)
1 : Forward running
0 : Other than reverse running
2
(during stop or forward rotation)
1 : Reverse running
0 : OFF
3
1 : ON (up to frequency)
0 : OFF
4
1 : ON (overload alarm)
5
Not used (0 is returned)
0 : OFF
6
1 : ON (output frequency being
detected)
0 : Inverter normal
7
1 : Inverter alarm occurrence
8 to 15 Not used (0 is returned)
0 to 15 Not used (0 is set)
Definition
• For master-to-slave messages (command
request), bits 0 to 7 are not used and must
be set to 0. The bit-wise data here do not
reflect Pr.190 to Pr.192 (output terminal
function selection).
• At command response, signals are the
same. Signals are not affected by settings
of Pr.190 to Pr.192 (output terminal function
selection).