Mitsubishi Electric FR-E720-0.1K Instructions Manual page 58

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

Name
High speed operation
command
(Terminal RH function)
Middle-speed
operation command
(Terminal RM function)
Low-speed operation
ECW
command
(Terminal RL function)
Terminal 4 input
selection (AU signal)
Command count
Up to frequency
(SU signal)
Overload alarm
ESW
(OL signal)
Command count
Reserved
Bit
0
Functions assigned to terminal RH, RM, RL are activated.
(Signal names are initial values. Using Pr.180 to Pr.182, you can change
1
output signal functions.
Refer to the inverter manual for details of Pr.180 to Pr.182.)
2
3
Not used (0 is set)
0: OFF
4
1: ON (Terminal 4 input is the main speed setting)
5 to 7
Not used (0 is set)
8 to 15 Used by the master to recognize the command response.
0: OFF
0
1: ON (Output frequency has reached the set frequency)
0: OFF
1
1: ON (Overload alarm occurrence)
2 to 7
Not used (0 is set)
8 to 15 Echo back of the command request.
0 to 15 Not used (0 is set, 0 is returned)
PPO TYPE SUPPORT SPECIFICATION
Definition
7
51