GB3836.15-2000 "Electrical apparatus for explosive gas atmospheres Part 15: Electrical
installations in hazardous area (other than mines)"
GB3836.16-2006 "Electrical apparatus for explosive gas atmospheres Part 16:
Inspection and maintenance of electrical installation (other than mines)"
GB50257-1996 "Code for construction and acceptance of electric device for explosion
atmospheres and fire hazard electrical equipment installation engineering"
N3 China Type n
Certificate: 3051S: GYJ15.1106X [Mfg China]
Markings: Ex nA IIC T5 Gc
Special Conditions for Safe Use (X):
1. The ambient temperature range is: -40 °C ≤ T
2. Maximum input voltage: 45 V
3. Cable glands, conduit or blanking plugs, certified by NEPSI with Ex e or Ex n protection
type and IP66 degree of protection provided by enclosure, should be used on external
connections and redundant cable entries.
4. Maintenance should be done in non-hazardous location.
5. End users are not permitted to change any components inside, but to settle the problem
in conjunction with manufacturer to avoid damage to the product.
6. When installation, use and maintenance of this product, observe following standards:
GB3836.13-2013 "Electrical apparatus for explosive gas atmospheres Part 13: Repair
and overhaul for apparatus used in explosive gas atmospheres"
GB3836.15-2000 "Electrical apparatus for explosive gas atmospheres Part 15: Electrical
installations in hazardous area (other than mines)"
GB3836.16-2006 "Electrical apparatus for explosive gas atmospheres Part 16:
Inspection and maintenance of electrical installation (other than mines)"
GB50257-1996 "Code for construction and acceptance of electric device for explosion
atmospheres and fire hazard electrical equipment installation engineering".
4.10 EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.AA87.B.00094
Markings: Ga/Gb Ex d IIC T6...T4 X
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.AA87.B.00094
Markings: 0Ex ia IIC T4 Ga X
4.11 Japan
E4 Japan Flameproof
Certificate: TC15682, TC15683, TC15684, TC15685, TC15686, TC15687, TC15688,
Markings: Ex d IIC T6
4.12 Republic of Korea
EP Republic of Korea Flameproof
Certificate: 12-KB4BO-0180X [Mfg USA], 11-KB4BO-0068X [Mfg Singapore]
Markings: Ex d IIC T5 or T6
3051SF: GYJ15.1107X [Mfg China]
TC15689, TC15690, TC17099, TC17100, TC17101, TC17102, TC18876
3051ERS: TC20215, TC20216, TC20217, TC20218, TC20219, TC20220,
TC20221
≤ 85 °C.
a
Quick Start Guide
23