Information On The Application Of Motors; Transport / Storage Before Use; Environmental Conditions - Siemens 1FT7 Configuration Manual

Sinamics s120 series synchronous motors
Hide thumbs Also See for 1FT7:
Table of Contents

Advertisement

Information on the application of motors

7.1

Transport / storage before use

During transport and if the motors are out of operation for a long period of time, the cooling
circuit must be completely drained to protect against frost damage and corrosion.
The motors should be stored indoors in dry conditions with low-dust and low vibration levels
(v
eff
temperature (+5° C to +40° C) to retain the service life of the grease.
Observe the additional notes regarding transport and storage in the operating instructions.
7.2

Environmental conditions

Operating temperature range: -15° C to +40° C (without any restrictions).
All of the catalog data refer to an ambient temperature of 40° C, mounted so that the motors
are not thermally insulated and an installation altitude up to 1000 m above sea level.
Under conditions other than those specified above (ambient temperature > 40°C or
installation altitude > 1000 m above sea level), the permissible torque/power must be
determined using the factors from the following table.
Ambient temperatures and installation altitudes are rounded-off to 5° C or 500 m
respectively.
Table 7- 1
Installation altitude above
sea level [m]
1FT7 Synchronous Motors
Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
< 0.2 mm/s). The motors should not be stored longer than two years at room
Factors to reduce the torque/power (de-rating)
1000
1500
2000
2500
3000
3500
4000
Ambient temperature in ° C
< 30
30 - 40
1,07
1,00
1,04
0,97
1,00
0,94
0,96
0,90
0,92
0,86
0,88
0,82
0,82
0,77
45
50
0,96
0,92
0,93
0,89
0,90
0,86
0,86
0,83
0,82
0,79
0,79
0,75
0,74
0,71
7
55
0,87
0,84
0,82
0,78
0,75
0,71
0,67
231