Motor components
5.3 Holding brake (option)
Table 5- 4
Electr.
component
F
K1
R2
Figure 5-3
5.3.5

Technical data of the holding brake

Table 5- 5
Technical data of the holding brakes used for 1FT7 Compact motors
Motor type
Brake
designation
1FT703⃞
HT04P01
1FT704⃞
HT07P01
1FT706⃞
HT09P01
1FT708⃞
HT11P01
1FT710⃞
HT14P01
210
Example: Electronic components for the recommended circuit
3RV10 circuit-breaker with current
paths connected in series (if
required with mounted auxiliary
contact 3RV1901 to provide a
feedback signal for the drive).
Auxiliary contactor 3RH11
Varistor SIOVS14K30 (EPCOS)
Terminology (time) for holding operation
Holding
Min. braking
torque
torque
M
M
4
1
at 120° C
[Nm]
[Nm]
3
1,5
8
5
18
11
48
25
85
35
Examples
or
Miniature circuit-breaker 5SX21 (if
required with mounted auxiliary contact
to provide a feedback signal for the
drive).
or
Contactor 3RT10
DC current
Opening
at 20 °C
time with
with varistor
[A]
[ms]
0,3
60
0,6
90
0,8
150
1,0
220
1,6
250
Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
Closing time
Highest
switching
with varistor
energy
[ms]
[J]
25
30
30
270
50
880
65
1900
70
5300