Compaq PowerStorm 1000 Owner's Manual page 90

Digital graphics subsystem
Table of Contents

Advertisement

Event Log Messages
Table D-1 (cont.) Windows NT Event Log Messages
Message
No supported VOM
detected.
Only one Image
Rendering Module
detected - System
Performance
Degraded.
Invalid texture
memory
configuration
detected
Invalid PixLink
memory
configuration
detected.
Event data has been
lost.
A Local Bus parity
error has been
detected.
An Hbus time-out
error has been
detected.
D–2 DIGITAL PowerStorm 1000 Graphics Subsystem Owner's Guide
Parameters
Description
VOM Type
The VOM type code read from the Graphics
Code
Interface Module Status registers was not x
indicating that a Standard Resolution Module
was present or y indicating that a High
Resolution Module was present. The Type Code
displayed is the value of the type code bits that
were contained in the Graphics Interface
Module Status register.
IRM Mask
Only one Image Rendering Module was
detected. IRM Mask will be 1 – the value of the
Image Rendering Module configuration bits
read from the Graphics Interface Module Status
register.
IRM0 TM Size
Either no texture memory is installed on any
IRM1 TM Size
Image Rendering Module or the Image
IRM2 TM Size
Rendering Modules installed have different
IRM3 TM Size
amounts of texture memory. The parameter
values indicate the amount of texture memory
installed on each Image Rendering Module
specified in MB, the size will be zero for an
Image Rendering Module that is not installed.
IRM0 PLM Size
The Image Rendering Modules installed have
IRM1 PLM Size
different amounts of PixLink memory. The
IRM2 PLM Size
parameter values indicate the amount of
IRM3 PLM Size
PixLink memory installed on each Image
Rendering Module specified in MB, the size
will be zero for an Image Rendering Module
that is not installed.
Number of lost
Events are being generated faster than they can
events
be logged and some event messages have been
discarded. The parameter value indicates the
number of events that have been discarded.
Workstation
The Workstation Interface Board has detected a
Interface Board
parity error on it's local bus. The parameter
Status Register
value is the contents of the Workstation
Interface Board Status register.
Workstation
The Workstation Interface Board has detected a
Interface Board
Hbus time-out. The parameter value is the
Status Register
contents of the Workstation Interface Board
Status register.

Advertisement

Table of Contents
loading

Table of Contents