Table 40-14: Coder Parameters - AudioCodes Mediant 8000 Installation, Operation & Maintenance Manual

Table of Contents

Advertisement

Parameter
Name
Name
String
Up to 20 chars.
Coder Name
Enum
G.711 A-law, G.711 U-
law, G.729, G.723.1,
G.726, GSM-FR, GSM-
EFR, MS-GSM, NetCoder,
AMR, EVRC, Transparent,
QCELP, iLBC, EVRC-B
4GV, G.722, AMR-WB,
T.38, G.711A-law_VBD,
G.711U-law_VBD,
EG.711 A-law, EG.711 U-
law, G.729.1, MS RTA
NB, MS RTA WB
Packetization
Enum
Time
default, t10ms, t20ms,
t30ms, t40ms, t50ms,
t60ms, t70ms, t80ms,
t90ms, t100ms, t110ms,
t120ms, t130ms, t140ms,
t150ms
Coder
Enum
Rate(kbps)
0 – 64000
Payload Type
Integer
0-120
Silence
Enum
Suppression
Disable, Enable,
EnableWithoutAdaptations
Installation & Operation Manual

Table 40-14: Coder Parameters

Type
Provisioning
Type
Online
Online
Online
Online
Online
Online
610
Description
Easily identifiable user-defined Coder
name
Defines Coder name.
Each Coder Name may appear in Coder
Table only once.
Defines packetization time (in
milliseconds).
Determines how many coder payloads
are combined into a single RTP packet.
If not specified, the ptime gets a default
value.
The ptime specifies the packetization
time the gateway expects to receive.
The gateway always uses the ptime
requested by the remote side for
sending RTP packets.
Defines coder bit rate (in Kbps).
Defines payload type.
Applicable to coders with dynamic
payload only. Specifies the format of the
RTP payload. If not specified – a default
is used.
Enables/disables the silence
suppression.
For G.729 it is also possible to select
the silence suppression without
adaptations.
Document # LTRT-92224