YASKAWA V1000 Technical Manual page 344

Compact vector control drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
Motor 2 Max
E3-04
Output Frequency
E3-05
Motor 2 Max
<1>
Voltage
Motor 2 Base
E3-06
Frequency
Motor 2 Mid Output
E3-07
Freq.
E3-08
Motor 2 Mid Output
<1>
Freq. Voltage
Motor 2 Min.
E3-09
Output Freq.
Motor 2 Min.
E3-10
Output Freq.
<1>
Voltage
E3-11
Motor 2 Mid Output
<7>
Frequency 2
E3-12
Motor 2 Mid Output
<1>
Frequency Voltage
<13>
2
E3-13
Motor 2 Base
<1>
Voltage
<9>
Motor 2 Rated
E4-01
Current
Motor 2 Rated
E4-02
Slip
Motor 2 Rated No-
E4-03
Load Current
Motor 2 Motor
E4-04
Poles
Motor 2 Line-to-
E4-05
Line Resistance
Motor 2 Leakage
E4-06
Inductance
Motor 2 Motor
Iron-Core
E4-07
Saturation
Coefficient 1
Motor 2 Motor
Iron-Core
E4-08
Saturation
Coefficient 2
Motor 2
E4-09
Mechanical Loss
E4-10
Motor 2 Iron Loss
Motor 2 Rated
E4-11
Capacity
344
Description
To set linear V/f characteristics, set the same values for
E3-07 and E3-09. In this case, the setting for E3-08 will be
disregarded.
Ensure that the five frequencies are set according to these
rules to prevent triggering an oPE10 fault:
E3-09 ≤ E3-07 < E3-06 ≤ Ε3−11 ≤ E3-04
Note: Setting E3-11 to 0 disables both E3-11 and E3-12,
and the above conditions do not apply.
VACrms Out (V)
E3-05
E3-12
E3-13
E3-08
E3-10
E3-09 E3-07
Frequency (Hz)
E4: Motor 2 Parameters
Use E4 parameters to control a second motor operating on the same drive.
Sets the motor 2 nameplate full load current in amperes
(A). This value is automatically set during Auto-Tuning.
Sets the motor 2 rated slip in Hz. Automatically set during
Auto-Tuning.
Sets the magnetizing current of motor 2 in Ampere.
Automatically set during Rotational Auto-Tuning.
Sets the number of poles of motor 2. This value is
automatically set during Auto-Tuning.
Sets the phase-to-phase resistance of motor 2 in ohms.
Automatically during Auto-Tuning.
Sets the voltage drop due to motor leakage inductance as a
percentage of rated voltage of motor 2. Automatically set
during Auto-Tuning.
Set to the motor iron saturation coefficient at 50% of
magnetic flux. Automatically set during Rotational
Auto-Tuning.
Set to the motor iron saturation coefficient at 75% of
magnetic flux. This value is automatically set during
Rotational Auto-Tuning.
Sets the motor mechanical loss as a percentage of motor
rated power (kW) capacity.
Adjust in the following circumstances:
• When there is a large amount of torque loss due to motor
bearing friction.
• When there is a large amount of torque loss.
Sets the motor iron loss in watts.
Sets the motor rated capacity in kW. Automatically set
during Auto-Tuning.
E3-06 E3-11 E3-04
10 to 200%
than E4-01
0.0 to 40.0
Setting for
E4-07 to
0 to 65535
YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/f
LV
60 Hz
40.0 to
A
A
<19>
400.0
0.0 to
200.0 V
A
A
255.0
60 Hz
0.0 to
A
A
<19>
E3-04
3.0 Hz
0.0 to
<12>
A
A
E3-04
<19>
16.0 V
0.0 to
<6>
A
A
255.0
<12>
1.5 Hz
0.0 to
<12>
A
A
E3-04
<19>
12.0 V
0.0 to
<6>
A
A
255.0
<12>
0.0 to
0.0 Hz
A
A
E3-04
0.0 to
255.0
0.0 Vac
A
A
<1>
0.0 to
255.0
0.0 Vac
A
S
<1>
of drive
<10>
A
A
rated
current
0.00 to
<10>
A
A
20.00
0 to less
<10>
A
A
<9>
2 to 48
4 poles
A
A
0.000 to
65.000
<10>
A
A
<11>
<10>
A
A
0.00 to
0.50
A
0.50
0.75
A
0.75
0.00 to
0.0
A
10.0
<10>
Α
0.00 to
<6>
A
A
650.00
Addr. Hex Pg.
PM
31A
167
31B
167
31C
167
31D
167
31E
167
31F
167
320
167
345
167
346
167
347
167
321
168
322
168
323
169
324
169
325
169
326
169
343
169
344
169
33F
169
340
170
327
170