Basic Settings
1.6.6

Canceling a configuration change

Function
If the function is activated and the connection to the device is interrupted
for longer than the time specified in the field "Period to undo while
connection is lost [s]", the device then loads the last configuration saved.
Activate the function before you configure the device so that you will
then be reconnected if an incorrect configuration interrupts your
connection to the device.
Enter the "Period to undo while the connection is lost [s]" in seconds.
Possible values: 10-600 seconds.
Default setting: 600 seconds.
Note: Deactivate the function after you have successfully saved the
configuration. In this way you prevent the device from reloading the
configuration after you close the web interface.
Watchdog IP address
"Watchdog IP address" shows you the IP address of the PC from which
you have activated the (watchdog) function. The device monitors the link
to the PC with this IP address, checking for interruptions.