Control Using a DMX Controller:
1. The 3D Vision has 3 DMX channel modes; a 3 channel mode, 9 channel mode, and 13 channel
mode. See pages 6-9 for detailed description of the DMX values and traits. See the page 15 for
the pixel configurations.
2. To set your desired DMX channel mode and DMX address follow the instructions on page 11.
3. When connecting to a DMX controller or using MyDMX, you will need to use a RJ45 to 3pin
adapter. This can be purchased through ADJ.
4. Connect the first unit to the adapater and then connect to either your DMX controller or MyDMX.
5. Follow the DMX traits on pages 6-9 to control your unit.
DO NOT daisy-chain more than 32 Panels when connecting directly to a DMX controller.
3D Vision Plus

Master-Slave Configuration:

This function will allows you to link units together to run in a Master-Slave set-up. In a Master-Slave
set up one unit will act as the controlling unit and the others will react to the controlling units built-in
programs. Any unit can act as a Master or as a Slave however, only one unit can be programmed to
act as the "Master."
Master-Slave Connections and Settings:
1. Daisy chain your units via the etherCON connections located on the side of the unit.
2. Connect the first "Slave" unit to the "Master."
3. Press the MENU button until "SLAv" is displayed and press ENTER. For the "Master" unit press
the UP or DOWN buttons until 'NASt" is displayed and press ENTER. This now the "MASTER"
unit.
3. Set the "Master" unit to your desired mode of operation. On the "Slave" unit's press the MENU
button until "SLAv" is displayed and press ENTER. Press the UP or DOWN buttons until 'SLAv" is
displayed and press ENTER. The "Slave" unit(s) will now follow the "Master".
3D Vision Plus
With this feature you can connect the fixtures to one another using the powerCON input and
output sockets. The maximum that can be connected is 130 fixtures @ 120V and 250 fixtures @
240V. After the maximum connected fixtures you will need to use a new power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE 3D VISION PLUS AS
THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
ADJ Products, LLC - www.adj.com - 3D Vision Plus User Manual Page 13
Master-Slave Configuration

Multiple Unit Power Linking

DMX Control