C O N T E N T S General Information Limited Warranty (USA Only) Safety Guidelines Overview Virtual Swatch Colors Color Macro Chart Fixture Installation DMX Set Up DMX Addressing System Menu Dimmer Curve DMX Traits: Channel Functions & Values Remote Device Management (RDM) Error Codes Power Linking | Cleaning...
G E N E R A L I N F O R M AT I O N INTRODUCTION Please read and understand all instructions in this manual carefully and thoroughly before attempting to operate these products. These instructions contain important safety and use information. UNPACKING The products in this kit have been thoroughly tested and have been shipped in perfect operating condition.
All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product.
To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. ADJ Products, LLC is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation.
Page 7
S A F E T Y G U I D E L I N E S DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before servicing. DO NOT shake fixture;...
Page 8
LEDs. This issue is not specific only to ADJ lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
V I R T U A L S WAT C H C O L O R S VIRTUAL GEL SWATCH BOOK COLORS Filter Filter Filter Value Name Value Name Value Name Number Number Number Pale Yellow Pink Sky Blue Straw Medium Pink Pale Navy Blue Gold Tint...
C O L O R M A C R O C H A R T RGBW COLOR INTENSITY RGBW COLOR INTENSITY Color DMX Value Color DMX Value RED GREEN BLUE RED GREEN BLUE WHITE Color Macro 33 129-132 Color Macro 1 Color Macro 34 133-136 Color Macro 2 Color Macro 35 137-140...
F I X T U R E I N S TA L L AT I O N FLAMMABLE MATERIAL WARNING Keep fixture at least 7.9in. (0.2m) away from any flammable materials, decorations, pyrotechnics, etc. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations.
Page 13
F I X T U R E I N S TA L L AT I O N NOTICE: The suitable environmental temperature for this lighting fixture is between -20˚ C to 40˚ C. Do not place this lighting fixture in an environment where the temperatures are under or above the temperatures stated above.
Page 14
FIXTURE WILL NOT DROP IF THE CLAMP FAILS. The Focus Flex is fully operational in three different mounting positions, hanging upside-down, mount- ed sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 0.2m (7.9in.) away from any flammable materials (decoration etc.).
2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
DMX channels of each fixture. That means changing the settings of one channel will only affect the selected fixture. In the case of the Focus Flex, when in 16 Channel mode, you should set the starting DMX address of the first unit to 1, the second unit to 17 (1 + 16), the third unit to 29 (17 + 16), the forth unit to 49 (33 + 16), and so on and so forth, et cetera.
SYSTEM MENU The fixture includes an easy to navigate system menu. The control panel located on the front of the fixture, provides access to the main system menu and is where all necessary system adjustments are made to the fixture. During normal operation, pressing MODE button once will access the fixture’s main menu.
Page 18
S Y S T E M M E N U Menu Sub Menu Description OPTIONS / VALUES (Default Settings in BOLD) Basic 16 Standard 25 Extended 34 DMX Channel Extended 42 Mode Extended 50 Standard CMY 25 Extended CMY 28 Hold Last Blackout No DMX Status...
Page 19
S Y S T E M M E N U Menu Sub Menu Description OPTIONS / VALUES (Default Settings in BOLD) Standard Zoom Speed Fast Standard Stage Dim Modes Architectural Theatre Stage 2 Dim Speed 0.1S~10S LED Refresh 900~1500, 2500, 4000, 5000, 6000, 10KHZ, Rate 15KHZ, 20KHZ, 25KHZ, 1200HZ Linear...
Page 20
S Y S T E M M E N U Menu Sub Menu Description OPTIONS / VALUES (Default Settings in BOLD) Speed 000-255 Program 1 Fade 000-255 Program 2 Speed 000-255 Fade 000-255 Program 3 Speed 000-255 Fade 000-255 Program 4 Speed 000-255 Fade...
D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S Std. Ext. Ba. 16 Std. 15 Values Functions 000-255 PAN 8bit 540/630 Degrees 000-255 PAN FINE 16bit 000-255 TILT 8bit 270 Degrees...
Page 23
D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S Std. Ext. Ba. 16 Std. 15 Values Functions COLOR TEMPERATURE RED to GREEN No Function 001-255 Shift CT Red to Green...
Page 24
D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S Std. Ext. Ba. 16 Std. 15 Values Functions INTERNAL PROGRAMS 000-009 No Function 010-019 Program 1...
Page 25
D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S Std. Ext. Ba. 16 Std. 15 Values Functions SPECIAL FUNCTION (continued) 040-040 1190 Hz LED Refresh Rate 041-041 1210 Hz LED Refresh Rate...
Page 26
D M X T R A I T S : C H A N N E L F U N C T I O N S & VA L U E S Extended 50 Pixel Configuration Extended 42 Pixel Configuration Extended 34 Pixel Configuration...
R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
E R R O R C O D E S Error Codes subject to change without notice Print Error Message Description Error code PAN, TILT, Zoom, LED Temp, Base Temp, Head Fan, Base Fan...
P O W E R L I N K I N G With this feature you can connect the fixtures to one another using the power cable input and output sockets; which is 2 units @110v, and 6 units @240v. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
S P E C I F I C AT I O N S Light Source: Control: • 7 x 40-Watt RGBW LEDs (50,000 hr.) • 7 DMX Modes - 16/25/34/42/50/25 (CMY)/28 • CRI: 83 (CMY) Channels • CT: 6600K • Color LCD display with 6-button function menu •...
Page 32
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RADIO FREQUENCY INTERFERENCE WARNINGS &...