● User-friendly parameter assignment and configuration with TIA Portal technological object
(as of STEP 7 Basic / Professional V14 SP 1)
● Expanded functions for trained users:
– Address information for the "INIT" command no longer necessary
– Expanded "RESET" parameter
– The MDS-STATUS "Mode 3" functions with all transponder types
– Automatic antenna recognition with the reader RF350R (depending on the antenna)
Table 3- 2
Feature
Transponder protocol RF300
Transponder protocol ISO 15693
Transponder protocol ISO 14443
Multi-transponder mode
MOBY I emulation to the controller
Integrated setup help
LED display
Technology object "SIMATIC Ident"
Fast Command (MDS D1xx, D4xx,
D5xx)
With the TIA Portal as of STEP 7 Basic / Professional V14 SP 1
1)
3.2.2

RFID components and their function

System components overview
Table 3- 3
Component
Communications
module
Reader
Transponder
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Differences in the features
SIMATIC RF300
first generation
--
--
--
--
Single (3 colors)
--
--
RF300 system components
Description
A communications module is used to integrate the RF identification system in
controllers/automation systems.
The reader ensures inductive communication and power supply to the tran-
sponder, and handles the connection to the various controllers (e.g. SIMATIC
S7) through the communications module (e.g. ASM 456).
The transponder stores all data relevant for production and is used, for exam-
ple, instead of barcode.
System overview
3.2 SIMATIC RF300
SIMATIC RF300
second generation
--
Double (5 colors)