5.2.6
Metal-free area
The RF310R special version can be flush-mounted in metal. Allow for a possible reduction in
the field data.
Figure 5-5
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
5.2.7
Minimum distance between several readers
RF310R special version side by side
D ≥ 150 mm (with 2 readers)
D ≥ 200 mm (with more than 2 readers)
Figure 5-6
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Metal-free area for RF310R special version
Minimum distance between RF310R readers
5.2 SIMATIC RF310R with Scanmode
Readers
133