Siemens Simatic RF300 System Manual page 87

Hide thumbs Also See for Simatic RF300:
Table of Contents

Advertisement

Reader RF350R with ANT 18 and with RF300 transponders
Table 4- 48
Transponder
RF320T
RF330T
RF340T
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metal-
2)
lic surroundings.
Reader RF350R with ANT 18 and with ISO transponders (MDS D)
Table 4- 49
Transponder
MDS D124
MDS D127
MDS D160
MDS D324
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 18
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 10 mm
Flush-mounted in metal;
without surrounding clearance
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 18
Without metal
1)
On metal, distance 15 mm
Flush-mounted in metal;
distance all round 15 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal, distance 10 mm
Without metal
1)
On metal; distance 15 mm
Planning the RF300 system
4.3 Installation guidelines
ANT 18 without metal
100
85
75
100
120
2)
115
2)
95
100
65
60
ANT 18 without metal
100
85
85
100
95
60
100
85
100
90
ANT 18 mounted in met-
al
(10 mm all-round)
65
55
45
85
100
95
90
85
60
55
ANT 18 mounted in met-
al
(10 mm all-round)
85
75
45
90
85
60
80
75
80
75
87