When RFID modules are used, different components in the overall system can act as a
coupling path:
Table 4- 66
Coupling path
Conductors and cables
Control cabinet or housing
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Causes of coupling paths
4.5 Guidelines for electromagnetic compatibility (EMC)
Invoked by
Incorrect or inappropriate installation
Missing or incorrectly connected shield
Inappropriate physical arrangement of cables
Missing or incorrectly wired equalizing conductor
Missing or incorrect earthing
Inappropriate physical arrangement
Components not mounted securely
Unfavorable cabinet configuration