Planning the RF300 system
4.2 Field data for transponders, readers and antennas
Note
Relenace of the MDS E transponders
The MDS E transponders are products that will be discontinued. These are relevant for
migration projects in which existing RFID systems are replaced by SIMATIC RF300,
generation 2.
Note that the MDS E transponders can only be operated in conjunction with the readers of
the second generation!
Table 4- 19
MDS E600
MDS E611
MDS E624
All values are in mm
Table 4- 20
MDS E600
MDS E611
MDS E624
All values are in mm
Table 4- 21
MDS E600
MDS E611
MDS E624
All values are in mm
62
Field data RF310R reader
Length of the transmission
window (L)
80
80
45
Field data RF340R reader
Length of the transmission
window (L)
90
90
60
Field data RF350R reader / ANT 1
Length of the transmission
window (L)
70
100
55
Operating distance (S
)
a
2...30
2...40
2...25
Operating distance (S
)
a
5...50
10...50
2...35
Operating distance (S
)
a
10...50
10...50
2...35
System Manual, 07/2017, C79000-G8976-C345-07
Limit distance (S
)
g
43
60
36
Limit distance (S
)
g
65
65
45
Limit distance (S
)
g
60
65
45