Features of the RF300 reader
The reader provides inductive communication with the transponders and serial connection to
the communications modules.
Communication between the transponder and reader takes place over inductive alternating
fields.
The transmittable data volume between reader and transponder depends on
● the speed at which the transponder moves through the transmission window of the
reader.
● the length of the transmission window,
● the transponder type used (RF300- / ISO 15693- (MDS D)/ ISO 14443 transponder (MDS
E)),
● the memory type (FRAM, EEPROM; with RF300 transponders).
ISO 15693 functionality
With all readers of the RF300 family, you can use ISO 15693 transponders. Note that the
readers for RF300, ISO 15963 or ISO 14443 operation must have parameters assigned. The
parameter assignment done with the aid of the RESET frame (INIT-Run).
For more detailed information on software parameter assignment refer to the manuals.
● Function manual "Ident profile and Ident blocks
(https://support.industry.siemens.com/cs/ww/en/view/106368029)",
● Product Information "Input parameters for the RF300 system for programming via
communications modules
(https://support.industry.siemens.com/cs/ww/en/ps/15033/man)",
● Function manual "FB 45 (https://support.industry.siemens.com/cs/ww/en/view/21738808)"
as of version "AS ≥ A3".
ISO 14443 functionality
With all readers of the second generation of the RF300 family, you can use ISO 14443
transponders. The RF300 readers of the second generation therefore replace the MOBY E
readers SLG 72 and SLG 75. Note that the readers for RF300, ISO 15963 or ISO 14443
operation must have parameters assigned. The parameter assignment done with the aid of
the RESET frame (INIT-Run).
The following commands are supported in ISO 14443 operation of the readers:
● READ
● WRITE
SIMATIC RF300