5.3 SIMATIC RF310R - 2nd generation
5.3.11.1
Using the reader in hazardous area for gases
The temperature class of the reader for hazardous areas depends on the ambient
temperature range:
Ambient temperature range
-25 ℃ ... +70 ℃
Ignitions of gas-air mixtures
When using the reader, check to make sure that the temperature class is adhered to in
keeping with the requirements of the area of application
Non-compliance with the permitted temperature ranges while using the reader can lead to
ignitions of gas-air mixtures.
5.3.11.2
Using the reader in hazardous area for dust
The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are
higher than 80 °C (smoldering temperature).
Ambient temperature range
-25 °C < Ta < +70 °C
Ignitions of dust-air mixtures
When using the reader, check to make sure that the temperature values are adhered to in
keeping with the requirements of the area of application. Non-compliance with the permitted
temperature range while using the reader can lead to ignitions of dust-air mixtures.