Appendix D: Hazardous Area Installation

WARNINGS:
• Turn off power before servicing any device.
• Please check the ambient and operating temperatures under
Environmental
configuration you are about to use or install.
• In potentially explosive atmospheres:
- open the enclosure only when Pointek CLS200/300 is not
energized.
- if a transmitter is to be used as category 1/2 equipment, please
check the product nameplate, and see
Nameplates
The transmitter is in operation when the power supply is switched on.
Note:
Instructions specific to hazardous area
installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number KEMA
00ATEX2039X and KEMA 00ATEX2040X:
1.
For use and assembly, refer to the main instructions.
2.
The equipment is certified for use as Category 1/2G, 1/2D. Refer to appropriate
certificate.
3.
Refer to appropriate certificate for application in specific hazardous environment.
4.
Refer to appropriate certificate for ambient temperature range.
5.
The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
6.
Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 60079-14 and
EN 60079-17 in Europe).
7.
Repair of this equipment shall be carried out by suitably trained personnel in
accordance with the applicable code of practice (e.g. EN 60079-19 within Europe).
8.
Components to be incorporated into or used as replacements in the equipment shall
be fitted by suitably trained personnel in accordance with the manufacturer's
documentation.
9.
The certificate numbers have an 'X' suffix, which indicates that special conditions
for safe use apply. Those installing or inspecting this equipment must have access
to the certificates.
10. If the equipment is likely to come into contact with aggressive substances, then it is
the responsibility of the user to take suitable precautions that prevent it from being
adversely affected, thus ensuring that the type of protection is not compromised.
Aggressive substances: e.g. acidic liquids or gases that may attack metals, or
solvents that may affect polymeric materials.
Page 44
Pointek CLS200/300 Standard – INSTRUCTION MANUAL
Process
on page 9, and
, page 42 onwards, to verify the protection type.
on page 10 for the specific
Appendix C: Product
7ML19985JH01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pointek cls300

Table of Contents