Table 2- 2
SEP
PED
PED*
N/A
N/A*
All products sold outside of EU and EFTA are excluded from the Pressure Equipment
directive, also products sold into certain market sectors are excluded. These include
1. Meters used in networks for the supply, distribution and discharge of water.
2. Meters used in pipelines for the conveyance of any fluid from offshore to onshore.
3. Meters used in the extraction of petroleum or gas, including christmas tree and manifold
4. Any meter mounted on a ship or mobile offshore platform.
2.2

Installation in hazardous area

Equipment used in hazardous areas must be Ex-approved and marked accordingly.
It is required that the special conditions for safe use provided in the manual and in the Ex
certificate are followed!
Hazardous area approvals
The device is approved for use in hazardous area and has the following approvals:
MAG 3100 Ex DN 350-2000:
● Ex e ia IIC T3-T6 Gb Ex tD A21 IP67 T*°C (* pipe temperature +5 K) (remote mounted)
● Ex d e [ia] ia IIC T3-T6 Gb Ex tD A21 IP67 T**°C (** pipe temperature +5 K, but not less
MAG 3100 Ex DN 15-300:
● Ex de ia IIC T3-T6 Gb Ex tD A21 IP67 T*°C (* pipe temperature +13 K) (remote mounted)
● Ex de* [ia] [ib] ia ib* IIC T3-T6 Gb Ex tD A21 IP67 T**°C (** pipe temperature +13 K, but
* The "e" and "ib" markings on the compact version are only applicable if the "Ex e"
supply/data terminal chamber option is used.
SITRANS F M MAG 3100 sensor
Operating Instructions, 09/2012, A5E03005599-02
PED table key
Excluded from PED under SEP (Sound Engineering Practice)
Product covered by PED and only available as fully PED-conforming
Product covered by PED but available as either conforming or non-conforming to
PED
Size/pressure outside of PED scope or not available in the size range
DN1400-2000 only available non conforming to PED
CAUTION
equipment.
WARNING
than 85°C) (compact mounted)
not less than 85°C) (compact mounted)
Safety notes
2.2 Installation in hazardous area