Available languages

4.3 Determining the Direction of Connection of
the Phase Wires to a Motor
.
1.
Connect the three leads to the instrument, matching the
markings.
2.
Connect the three alligator clips to the three phase connections
on the motor being tested.
3.
Press the ON (TEST) button. The Green LED indicator indi-
cates that the instrument is in operation.
4.
Rotate the motor shaft to the right at a few RPM's to get a
stable reading on one of the LED rotations.
5.
The clockwise or counter-clockwise rotation indicator lights,
indicating whether or not the order of connection of the phase
wires is correct.

4.4 Solenoid Valve Activation Indication

1.
Do not connect any test leads to the instrument
2.
Place the instrument as close as possible to the solenoid
valve.
3.
Press the ON button. The Green LED indicator indicates that
the instrument is in operation.
4.
The clockwise or counter-clockwise rotation indicator lights,
indicating the presence of the field generated during the acti-
vation.
Phase & Motor Rotation Tester Model 6609