SMC Networks PF2A712H Operation Manual page 39

Pf2a7 series digital flow switch (integrated display type)
Table of Contents

Advertisement

Model
Voltage output
Current output
Accuracy
Response time
Display accuracy
Display part
Indicator LED (output)
Supply voltage
Power consumption (no load)
Enclosure
Operating temperature range
Operating humidity range
Temperature characteristics
Withstand voltage
Insulation resistance
Standards and regulations
Port size (Rc, NPT, G)
Materials of parts in contact with fluid
Product
Lead wire and connector
1: Display flow range in the specification is the value at standard condition.
If the display unit is changed from standard [ANR] to normal [nor], use the following conversion formula.
Flow rate at standard condition x 0.927 = Flow rate at normal condition
2: If the flow rate is smaller than the minimum flow of the display range, "0 L/min" is displayed.
3: Selectable by setting.
4: Standard condition: Flow display which is converted in atmospheric pressure at 20 C, 65%R.H.
Normal condition: Flow display which is converted in atmospheric pressure at 0 C.
: The form of the G thread (including the major and minor diameter and pitch of the internal thread) is based on JIS B0202 (ISO228-1).
Products indicated as ISO1179-1 (G thread for hydraulics) or ISO16030 (G thread for pneumatics) are based on JIS B0202
(ISO228-1) for effective depth of thread, seat surface area, surface roughness and squareness.
For ISO1179-1 (G thread for hydraulics), the withstand pressure is specified for each product. SMC do not guarantee the withstand
pressure specified in ISO1179-1, ISO1179-2, ISO1179-3, or ISO1179-4.
For ISO16030 (G thread for pneumatics), the withstand pressure is specified for each product. SMC do not guarantee the withstand
pressure specified in ISO16030.
Lead wire Specifications
Finished outside diameter
Sheath
Material
Colours
Insulator
Outside diameter
Nominal cross section area
Conductor
Outside diameter
PF2A703H
Output voltage: 1 to 5 V
Output impedance: approx. 1 kΩ
Output current: 40 to 20 mA
Load impedance: 250 Ω
5 digits, 7-segments, Colour display: Red
LED is ON when output is ON
Operation: 0 to 50 C, Storage: -25 to 85 C (no freezing or condensation)
Operation, Storage: 35 to 85%R.H. (no condensation)
±2%F.S. max. (0 to 50 C, 25 C reference)
1000 VAC, for 1 minute between the external terminals and case
50 MΩ or more (at 500 VDC)
between external terminals and case
1
A6063, H-NBR, SUS, PPS, PBT, Leaded glass/ptlr/FeNi/OFC, Grease
1.1 kg
approx. 4 mm
Oil-resistant PVC
Brown, White, Black, Blue
approx. 1.14 mm
AWG23
approx. 0.72 mm
-38-
PF2A706H
±3%F.S. max.
1 s or less
±1.5%F.S. max.
24 VDC ±10%
150 mA or less
IP65
CE, RoHS
1 1 / 2
1.3 kg
100 g
No.PF※※-OMG0010-G
PF2A712H
2
2.0 kg

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf2a706hPf2a703h

Table of Contents