Enclosure and mounting of the module.

2.4.1
Enclosure design.
The enclosure must meet the following requirements:
• The degree of protection of the enclosure must be IP54, according to standard IEC
60529.
• Keep the enclosure clean.
• The dissipation surface of the enclosure must be enough to evacuate (by convection)
the heat generated inside.
• In the connector area, reserve a space that allows the cables to be connected, respecting
their radius of curvature.
• Respect the minimum distances recommended between the enclosure walls and the
hardware to let the air flow and improve heat dissipation.
To meet the previous requirements, Fagor recommends the following.
i
• The enclosure must not have any ventilation holes, because they could let dust or other substances
in.
Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor
i
Automation.
Dimensions of the cut off part and the enclosure.
Radius of the corners = 5 mm (0.2 inches).
W
H
W
H
mm
inch
550,30±1,0
21,67±0,040
341,80±0,7
13,46±0,025
mm
inch
D (*)
75
2.95
(*) Minimum recommended distance.