Wire Map

Wire map results show the connections between the main
and remote testers. The tester checks the cable pairs
required by the selected test limit. If the wire map test fails,
you can continue or stop the Autotest.
Correct wiring (568B)
Shield continuity is shown if a shielded
cable type (such as FTP or SSTP) is selected
in SETUP.
amd143i.bmp
Wire 3 is open 1.0 m from the tester and
91.6 m from the smart remote.
Figure 3-8. Wire Map Examples
Certifying Twisted Pair Cabling
Twisted Pair Autotest Results
Tip: The wire map test in Single Test mode features a
scanning function that runs the wire map test
continuously. This function is helpful for locating
intermittent wiring faults.
Figure 3-8 describes examples of wire map screens. For
information on AC wire map screens, see Chapter 4.
amd144i.bmp
Open
Wires 1 and 2 are shorted 1 m from the
smart remote. Shorts not within a
cable pair are always show at the near
end (left side) of the wire map screen.
3
amd81i.bmp
Short
-continued-