Mounting the barndoors

Warning
For safety reasons we do not recommend that this procedure be performed while the
fixture is rigged.
1 Referring to the instructions in the MAC 2000 Wash user manual (P/N 35000114), set the personality
settings on the MAC 2000 Wash to match the lens that is installed in the barndoor unit. If the PC lens is
installed then use the control panel to set PERS>bdL>PC L. For all other lens, including the standard
diffuser lens, use the default setting, PERS>bdL>dF L.
2 Disconnect the MAC 2000 Wash fixture from power.
3 Lock the fixture head in the "top" horizontal position.
4 If present, remove the lens that is installed on the MAC 2000 Wash by unscrewing the four quarter-turn
screws, pulling the lens housing away from the fixture, and releasing the safety cable.
5 Attach the barndoor safety cable to the MAC 2000 Wash and lock it in place using the thumb-screw. Ensure
that the cable slack is kept away from the optical path.
Mounting and operating the barndoor unit