Ethernet Connection - W&T 58620 Manual

Lan-modem
Table of Contents

Advertisement

W&T
3.1

Ethernet connection

The LAN-Modem incorporates an IEEE 802.3-compatible
network interface.
Link-Status
The current link status of all models is indicated by the Error
LED on the device front panel. Flashing at a rate of approx. 1
second indicates that there is no connection to the hub or that
the connection is faulted.
3.1.1 10/100BaseT on RJ45
The LAN-Modem has a 10/100BaseT network interface on a
shielded RJ45 connector. The pin assignments shown below
correspond to an MDI interface, so that the connection to the
hub or switch is made using a max. 100m long 1:1 shielded
patch cable.
1 2 3 4 5 6 7 8
The network connection is galvanically isolated with respect to
the supply voltage as well as the serial interface(s) for at least
500V
.
rms
Auto Negotiation: 10/100BaseT, Full/Half Duplex
LAN-Modems are factory set to operate in Auto-Negotiation
mode on the network side. The data transmission speed and
duplex are automatically negotiated with the connected switch/
hub and set accordingly.
24
Signal
Pin
Direction
Tx+
1
Out
Tx-
2
Out
Rx+
3
In
nc
4
In
nc
5
In
Rx-
6
In
nc
7
In
nv
8
In