Mounting a Sensor Head

Place a sensor head on the two posts. It does not matter on which side Head A or
Head B is mounted — the heads will be configured in the analyzer. Adjust to desired
position and tighten each post clamp finger tight. The mounting posts allow up to
1.5 inches (38 mm) of vertical adjustment. If more vertical adjustment is needed,
use the vertical extension blocks. See "Introduction to Special Applications" on
page 2-46 through "Adding a 2-inch (51 mm) Block" on page 2-48 for additional
information.
2-28
Note
The gray sensor head with the laser source on top is designated head
"A". The "B" designation is attached to the blue sensor head with the
laser source on the bottom. In addition to their color difference,
head A and B are identified with letters on the front panel.