Max/Min Function; Rel Function; Manual Range Mode - AEMC 511 User Manual

Clamp-on meter
Table of Contents

Advertisement

4.1.3
• The Models 511 and 512 are built with MAX/MIN func-
tion at A
• Pressing the MAX/MIN button once will set the meter
to MAX mode.
• Pressing it twice will set the meter to MIN mode.
• Pressing it three times will display the present reading
and still keep track of the MAX and MIN change. This
mode will also indicate a blinking MAX/MIN symbol.
• Pressing the MAX/MIN button for more than 2 seconds
will set the meter back to normal operation.
4.1.4
• The Models 511 and 512 are built with REL function at
A
AC
• Pressing the ∆REL button once will change the zero to
the present reading and the relative value will show on
the LCD.
• Pressing it twice will display the relative zero point. This
mode will also indicate a blinking
• Pressing the ∆REL button for more than 2 seconds will
set the meter back to normal operation.
4.1.5
• The Models 511 and 512 operate in an Auto-ranging
mode (AUTO displayed) by default. Manual-ranging in
V
AC/DC
• Press and hold the RANGE button. When the range
changes (decimal point shift), release the button.
• The
• Press and hold the RANGE button for more than 2 sec-
onds to re-enter the Auto-ranging mode.
12
Shop for AEMC products online at:

MAX/MIN Function

, V
and V
AC
AC

REL Function

, V
and V
AC
DC

Manual Range Mode

, and A (1000A) is available.
symbol is displayed in the manual range mode.
www.
ranges.
DC
ranges.
Clamp-on Meter Models 511 and 512
ShopAEMC
symbol.
.com
1.888.610.7664