8 Technical data

Measuring principle
Thermal: hot-film anemometer
Input
Measured medium
Air
1)
Measuring ranges
0 (1)...100 kg/h or
2)
0 (12)...1250 Nl/min
Output
Analog output signal
0... 5 V
0...10 V
0/4...20 mA,
Load
< 500 Ω
Error message
< 3,5 mA oder > 22 mA
Digital output signal
24 V, 20 mA
Frequency output signal
variable 1...2500 Hz
Totalizer
Pulse evaluation adjustable
Pulse duration adjustable
Alarm values
Minimum and maximum, adjustable
Polarity adjustable
Performance characteristic, measurement accuracy
Measured error
< ± 3,0 % of measured value
Repeatability
< ± 0,5 % of measured value
Setting time
≈ 25 ms
T
63
≈ 90 ms
T
98
Influences
Temperature effect
< 0,1 %/K of measured value
Pressure effect
≤ 0,2 %/100 kPa (/bar) of measured value
Pressure drop
< 10 kPa (100 mbar)
at full scale and use of the KF flange adapter DN 25
decreasing quadratically with smaller flow rates
approx. 15 mbar at operation without special sieve and at full
scale flow rate.
1) Approximate values are given for applications with air under atmoshperic con-
ditions. The values in brackets indicate the lower limit of the measuring range
for which the measured value accuracy indicated is specified.
2) It is possible to specify any unit which you can transform into a mass or stan-
dard volume flow. For Example 1 ballon/min = 7 l/min - q
24
Thermal Mass Flowmeter FMT200-ECO2
Operating conditions
Mounting conditions
Up- and downstream lengths see Installation and start-up
Ambient conditions
Ambient temperature transducer 0...50 °C
Degree of protection
Storage temperature
Measured medium conditions
Operating temperature
Maximum operating pressure
Standard
High pressure version
Construction
Weight
0,51 kg
(Accessories: see ordering information)
Material
Transducer
Process connections
Fittings
Process connection
see ordering information
Electrical connection
Sub-D connector, series 712, 8 pins, IP 65
Power supply
Voltage
24 V DC ± 10%
Power consumption
< 15 W
Current
Peak
Operation
Interface
RS 232
Ex Version
II3 G EEx n A II T4 X ( Zone 2, Gas)
II3 D T 135°C IP65 X ( Zone 2, Dust)
Accessories
– Entry and exit length
– Pipe fittings
– Adapters
– Quick-clamping connectors
– Reducers
– Power supply unit
– Display unit
– Display and supply unit completely mounted in an
IP 65 housing
3) 24 V DC power supply with safe isolation according to EN 61010 and
IEC 950, with a maximum output of < 150 W only.
.
n
Technical data
IP 65
-25...85 °C
0...50 °C
10 × 10
2
kPa (= 10 bar)
16 × 10
2
kPa (= 16 bar)
aluminium, Hostadur,
Cu tinned, glass
aluminium
aluminium
3)
< 1 A
< 0,6 A
(optional)
42/14-41 EN