Maintenance Instructions; General Vent Maintenance; Glass Gasket; Glass Door - Regency Fireplace Products Greenfire GFi350LNG-R Owners & Installation

Gas inbuilt fireplaces
Table of Contents

Advertisement

maintenance
MAINTENANCE
INSTRUCTIONS
1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
2. Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a
gas fireplace glass cleaner. The glass should
be cleaned when it starts looking cloudy.
3. The faceplate is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency® uses StoveBright
Paint - Metallic Black #6309.
Note: Faceplates and inner panels made from
stainless steel will naturally change
color over time.
4. Make a periodic check of burner for proper posi-
tion and condition. Visually check the flame of
the burner periodically, making sure the flames
are steady; not lifting or floating. If there is a
problem, call a qualified service person.
5. The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
Note: Never operate the appliance without the
glass properly secured in place.
6. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
7. In the event this appliance has been serviced
check that the vent-air system has been properly
resealed & reinstalled in accordance with the
manufacturer's instructions.
8. Verify operation after servicing.
30
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1. Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
3. Check for evidences of excessive condensa-
tion, such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.

GLASS GASKET

If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).

GLASS DOOR

Your Regency
fireplace is supplied with high
®
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the glass
front or with a cracked or broken glass front.
* Wear gloves when removing damaged or broken
glass.
* Replacement of the glass panel(s) should be
done by a licensed or qualified service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
dealer only.
®
Replacement glass is shipped already installed
into the door frame.
CAUTION: Wear gloves when removing
damaged or broken glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualified service person.
Regency GFi350L Gas Fireplace Inbuilt

Advertisement

Table of Contents
loading

Table of Contents