Faceplate & Trim Installation - Regency Fireplace Products Greenfire GFi350LNG-R Owners & Installation

Gas inbuilt fireplaces
Table of Contents

Advertisement

installation
FACEPLATE & TRIM INSTALLATION
1. Hang trim over glass door frame and lower gently.
2. Install 2 Faceplate brackets to the top of the unit with 3 screws each.
3. Lift Faceplate over brackets on top of unit--hook faceplate over brackets
and lower gently.
4. Install lower access panel, slide the 2 tabs located on the top of the ac-
cess panel into position and secure with 2 screws as shown below.
919-614a
24
FACEPLATE & TRIM INSTALLATION
5. Install lower access panel, slide the 2 tabs located on the top of the ac-
cess panel into position and secure with 2 screws as shown below.
6. Feed the wire from the digital box on the floor of the unit up through the
back of the faceplate and plug into the switch in the location shown.
7. Place power cord through opening located on the side of the faceplate and
secure with supplied grommet.
8. Slide glass through brackets as shown.
9. Secure logo plate to bottom left hand side of faceplate
1
GFI350L
wire from digital box
back of faceplate
09.06.17
Regency GFi350L Gas Fireplace Inbuilt