Installation and commissioning
1.
2.
3.
Note
Software version information may be verified in the device from the Field Communicator: Overview >
Device Information > Revision Number.
Figure 2-1:
A.
B.
Table 2-2:
Device
8800D firmware
8800D hardware
The safety certified output of the Rosemount 8800D is the 4-20 mA output. This output
provides a signal proportional to process flow, between low flow cutoff and the Upper
Range Value (URV). Detected faults are indicated by an offscale output (see
The safety logic solver should be configured to detect offscale output levels. While the
pulse output may be used, it is not a safety certified output. Devices ordered without SI
option are not certified per IEC 61508.
8
Verify the option code "SI" in the model code. The SI code will appear somewhere
after the 16th character of the model code (after the required fields.) Note that the
optional options, including SI, can appear in any order and be valid. Please refer to A
of
Figure
2-1.
For example: 8800D................SI
Verify 4-20mA marking on the transmitter housing nameplate. Please refer to B of
Figure
2-1.
Confirm firmware revision is 5.2.8. Please refer to
Example of transmitter nameplate
SI option code
4–20mA Output
Rosemount 8800D revisions and versions
Display tag
Universal revision
Transmitter revision
Software revision
Hardware revision
Table
2-2.
Version
5
2
8
1
Section
Rosemount
8800D Safety Manual