System Setup - Water Depot Deluxe Series Owner's Manual

Table of Contents

Advertisement

SYSTEM SETUP

STEP 1S – Press NEXT and ▼ buttons simultaneously for 3 seconds. If screen in
step 2S does not appear in 5 seconds the lock on the valve is activated. To unlock
press ▼, NEXT, ▲, and CLOCK in sequence, then press NEXT and ▼
simultaneously for 3 seconds.
STEP 2S – Use the ▲ or ▼ buttons to select 1.0 for WS1MR or 1.25 for the
WS1.25MR. Press NEXT to go to step 3S.
STEP 3S
STEP 3S – Allows selection of one of the following using the ▲ or ▼ buttons:
an outside signal to initiate a regeneration;
an outside signal to prevent or delay a regeneration.
Selecting the use of an outside signal to initiate a regeneration:
Selection only matters if a connection is made to the two pin connector labeled DP
SWITCH located on the printed circuit board. Following is an explanation of the
options:
Off - Feature not used. dPon0 - If the dP switch is closed for an accumulative time of 2
minutes a regeneration will occur immediately.
dPdEL - If the dP switch is closed for an accumulative time of 2 minutes a
regeneration will occur at the scheduled regeneration time.
HoLd - If the dP switch is closed a regeneration will be prevented from occurring.
Press NEXT to go to Step 4S.
STEP 4S
STEP 4S – Set Refill option using ▲ or ▼ buttons:
"PoST" to refill the brine tank after the final rinse; or
"PrE" to refill the brine tank four hours before the regeneration time set.
Press NEXT to go to Step 5S.
STEP 5S
STEP 5S – Set method for regeneration cycles by using the ▲ or ▼ buttons:
"Adj" allows manual setting of regeneration cycle times; or
Choose a P Code with fixed regeneration cycle sequences and times.
Press NEXT.
P CODE ADJ CYCLE
ON PAGE 10
ON PAGE 10
8S
8