Water Depot ECONO Series Owner's Manual

Water Depot ECONO Series Owner's Manual

Backwashable filter

Advertisement

Quick Links

OWNER'S MANUAL
FOR ALL BACKWASHABLE FILTER SYSTEMS
THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE AND PURPOSES AND
TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL
BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT
MALFUNCTION.
AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER DEPOT
PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE-FREE AND CONTINUOUS OPERATION.
www.waterdepot.com

Advertisement

Table of Contents
loading

Summary of Contents for Water Depot ECONO Series

  • Page 1 TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION. AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER DEPOT PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE-FREE AND CONTINUOUS OPERATION. www.waterdepot.com...
  • Page 2: Table Of Contents

    Backwashable Filter Setting Options ............10 Econo Control Valve Function and Cycles of Operation ......12 Backwashable Filter System Setup ............13 User Displays .................... 15 Troubleshooting Guide ................16 Water Depot 92 Commerce Park Drive, Unit 2 Barrie, ON L4N 8W8 www.waterdepot.com...
  • Page 3: Introduction

    Certain parts of the manual will serve as aids to manufacturers in the writing and layout of the manuals for installers and service personnel. Specifications ECONO SERIES BACKWASHABLE FILTERS – 1500 ELECTRONIC TIMER PART NUMBER...
  • Page 4: Instructions

    Instructions The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments but are not designed to support the weight of a system or the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicon lubricant may be used on black o-rings but is not necessary.
  • Page 5: Installation Fitting Assemblies

    Installation Fitting Assemblies The installation fittings connect to the control valve or the bypass valve using nuts that only require hand tightening. Hand tighten nut connections between control valve and installation fittings, control valve and bypass valve, and bypass valve and installation fittings allow for easy serviceability. Do not use a pipe wrench to tighten nuts on installation fittings.
  • Page 7: Consumer Valve Programming Set-Up

    Consumer Valve Programming Set-up - Econo GENERAL OPERATION When the system is operating on of Two displays will be shown: time of day or days until the next regeneration. Pressing UP or DOWN will toggle Between the two choices. TO SET TIME OF DAY 1.
  • Page 8: Backwashable Filter System Setup

    Backwashable Filter System Setup - Econo In Filter System Setup choose the time for the cycles selected in Cycle Sequence and specifies other operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows: Cycle Options Units Lower/Upper Limit...
  • Page 9 Step 7F – Set Volume Capacity using the  or  button. If value is set to: • “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step 3I); or • as a number (allowable range 20 to 250,000) regeneration initiation will be based off the value specified.
  • Page 10: Backwashable Filter Setting Options

    Backwashable Filter Setting Options Gallons Regeneration Result Capacity Time Option Override Reserve capacity not automatically estimated. NORMAL Regeneration occurs at the next Regen Set Time when the number specified number of days between regenerations is reached. Reserve capacity not automatically estimated. NORMAL Regeneration occurs at the next Regen Set Time when gallons number...
  • Page 11 Regeneration Mode Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
  • Page 12: Econo Control Valve Function And Cycles Of Operation

    Econo Control Valve Function and Cycles of Operation This glass filled Noryl fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or filter. The time clock control valve can be set to perform downflow regeneration or simply backwash. The time clock control valve has two calendar options for regeneration frequency: 1.
  • Page 13: Backwashable Filter System Setup

    Backwashable Filter System Setup - Econo Installers Displays & Settings (1-99 Days Between Regeneration option) STEP 11D – From normal mode, press SET HOUR + UP buttons simultaneously for 3 seconds and release. STEP 21D – Regeneration Time: Set the clock to the hour the regeneration should occur by using the UP or DOWN buttons.
  • Page 14 Button until the arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur on Thursday. Press SET HOUR to go to STEP 917. STEP 917 – Friday Regeneration: To regenerate on Friday use the UP or DOWN button until the arrow points to Regen.
  • Page 15: User Displays

    User Displays - Econo General Operation When the system is operating one of two displays will be shown. Pressing UP or DOWN button will alternate between the displays. One of the displays is always the current time of day (to the nearest hour). The second display is the days remaining until next regeneration.
  • Page 16: Troubleshooting Guide

    Troubleshooting Guide - Platinum Problem Possible Cause Solution a. Transformer unplugged a. Connect power 1. Timer does not display b. No electric power at outlet b. Repair outlet or use working outlet time of day c. Defective transformer c. Replace transformer d.
  • Page 17 automatically when c. Broken drive gear or drive cap c. Replace drive gear or drive cap assembly assembly UP and DOWN buttons d. Defective PC board d. Replace PC board are depressed and held 7. Control valve does not a. Defective PC board a.

This manual is also suitable for:

Platinum seriesBtc1Btc2Btmc1Btcp1Btcp2