Installer Display Settings; Softener System Setup - Water Depot PLATINUM SERIES Owner's Manual

Hide thumbs Also See for PLATINUM SERIES:
Table of Contents

Advertisement

STEP 1I - Press NEXT and  simultaneously for 3 seconds.
STEP 2I – Hardness: Set the amount of hardness in grains of hardness as calcium
carbonate per gallon using the  or  buttons. The default is 20 with value ranges
from 1 to 150 in 1 grain increments. Note: The grains per gallon can be increased if
soluble iron needs to be reduced. This display will show "–nA–" if "FILTER" is selected
in Step 2F or if 'AUTO' is not selected in Set Volume Capacity in Softener System
Setup. Press NEXT to go to step 3I. Press REGEN to exit Installer Display Settings.
STEP 3I – Day Override: When volume capacity is set to "oFF", sets the number of days
between regenerations. When volume capacity is set to AUTO or to a number, sets the
maximum number of days between regenerations. If value set to "oFF", regeneration
initiation is based solely on volume used. If value is set as a number (allowable range
from 1 to 28) a regeneration initiation will be called for on that day even if sufficient
volume of water were not used to call for a regeneration. Set
Day Override using  or  buttons:
• number of days between regeneration (1 to 28); or
• "oFF".
See Table 8 for more detail on softener setup and Table 9 for more detail on filter setup.
Press NEXT to go to step 4I. Press REGEN to return to previous step.
STEP 4I – Next Regeneration Time (hour): Set the hour of day for regeneration using
 or  buttons. AM/PM toggles after 12. The default time is 2:00 AM. This display
will show "on 0" if "on 0" is selected in Set Regeneration Time Option in Softener
System Setup or Filter System Setup. Press NEXT to go to step 5I. Press REGEN to
return to previous step.
STEP 5I – Next Regeneration Time (minutes): Set the minutes of day for regeneration
using 
Regeneration Time Option in Softener System Setup or Filter System Setup. Press
NEXT to exit Installer Display Settings. Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the "REGEN" button for
three seconds. The system will begin to regenerate immediately. The control valve may
be stepped through the various regeneration cycles by pressing the "REGEN" button.
In Softener System Setup the chooses the time for the cycles selected in Cycle Sequence and species other
operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as
follows:
Cycle Options
Backwash
Rinse (fast)
dn Brine (combination of brining and slow rinse)
UP Brine (combination of brining and slow rinse)
Fill
Service
Note: Fill is in pounds of salt.
Since no time is associated with the END cycle, the END cycle will not appear in the Softener System Setup
sequence.

INSTALLER DISPLAY SETTINGS

or  buttons. This display will not be shown if "on 0" is selected in Set

SOFTENER SYSTEM SETUP

Page 6
Units
Lower/Upper Limit
Minutes
1 to 120
Minutes
1 to 120
Minutes
1 to 180
Minutes
1 to 180
LBS
0.01 to 200
Minutes
1 to 480
Default
8
4
60
60
9.5
240