P-Code 1
Selecting pre-set programs. If the unit
is set to 1.25, P60 - P69 will not be
available.
Select between
SOFTENING or FILT
P-Code 2
Set pounds of salt or gallons of
fill. Ranges and increments should
be as shown in Cycle Times table,
but can not be set to OFF.
P1 - P69 = lb (unit measure)
P70 - P79 = Gal (unit measure)
P80 - P99 = No Screen
Press NEXT to go to Step 7S
STEP 7S
System ionic capacity. Enter the ion exchange capacity
in grains of hardness as calcium carbonate for the system
based on test data using ▲or▼buttons. This screen is
not available except when configured P1 - P69 or an Adj
softener.
Press NEXT to go to Step 8S. Press REGEN to return
to the previous step.
Range (Grains)
5.0 - 50.0 x1000
50.0 - 200.0 x1000
200.0 - 500.0 x1000
STEP 8S - Set Gallons Capacity using
• "AUTO" (reserve capacity automatically estimated and gallons capacity automatically
calculated from grains capacity and water hardness);
• "oFF" (regeneration based on day override); or
• number of gallons (20 to 250,000).
Note: OFF will not be an option if days override is not set. Auto is not an option on a filter or P70 -
P88. See Setting Options Table for more details.
Press NEXT to go to Step 9S. Press REGEN to return to previous step.
THE
Increment
500
2,000
5,000
▲ or ▼
buttons:
9
Adj1
Select between
SOFTENING or FILT
THE
Adj2
Set upflow or downflow
regeneration on a 1" control.
This screen will not display if
the unit is set up as a1.25"
or filter valve.
Adj3
Set cycle times. OFF will be
an option in all cycles.
Press NEXT to go to Step
7S