Water Depot Deluxe Series Owner's Manual page 11

Table of Contents

Advertisement

10Step 9S – Set Regeneration Time Options using the ▲ or ▼ buttons:
TEP
• "NORMAL" means regeneration will occur at the preset time;
• "on 0" means regeneration will occur immediately when the gallons capacity
reaches 0 (zero); or
• "NORMAL + on 0" means regeneration will occur at one of the following:
• the preset time when the gallons capacity falls below the reserve or the specified
number of days between regenerations is reached, whichever comes first; or
• after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See Setting Options Table for more detail. Press NEXT to go to Step 10S. Press REGEN
to return to previous step.
Step 10S: Set Relay operation using the ▲ or ▼ button. The choices are:
• Set Time on: Relay activates after a set time at the beginning of a regeneration and
then deactivates after a set period of time. The start of regeneration is defined as
the first backwash cycle, Dn brine cycle or UP brine cycle which ever comes first.
• Set Gal on: Relay activates after a set number of gallons and then deactivates after
a set period of time or after the meter stops registering flow, whichever comes first.
• Set Off: If set to Off, Steps 11S and 12S will not be shown.
Press NEXT to go to Step 11S. Press REGEN to return to previous step.
Step 11S: Set Relay Actuation Time or Gallons using the ▲ or ▼ buttons. The choices
are:
• Relay Actuation Time: After the start of a regeneration the amount of time that
should pass prior to activating the relay. The start of regeneration is defined as the
first backwash cycle, Dn brine cycle or UP brine cycle which ever comes first.
• Relay Actuation Gallons: Relay activates after a set number of gallons has passed
through the meter.
Ranges from 1 to 50 gallons.
Press NEXT to go to Step 12S. Press REGEN to return to previous step.
Step 12S: Set Relay Deactivate Time using the ▲ or ▼ buttons.
• If Set Time on is selected in Step 10S the relay will deactivate after the time set has
expired. Ranges from 1 second to 200 minutes.
• If Set Gal on is selected in Step 10S the relay will deactivate after the time set has
expired or after the meter stops registering flow, whichever comes first. Ranges
from 1 second to 20 minutes.
Press NEXT to go to Step 13S. Press REGEN to return to previous step.
Step 13S: Set the Service Call Indicator using the ▲ or ▼ buttons. The choices are Time,
GAL or oFF.
• Time means a call indicator will be displayed after the preset time has expired. The
range is from .25 to 9.75 years.
• GAL means a call indicator will be displayed after the present number of gallons
has been used. The range is from 100 to 9,999,000 gallons.
Press NEXT to go to Step 14S. Press REGEN to return to previous step.
Step 14S: Use the ▲ or ▼ buttons to adjust Time or Gallons. Press NEXT to exit System
Setup.
Press REGEN to return to previous step.
10

Advertisement

Table of Contents
loading

Table of Contents