The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation.
These procedures are:
System Setup
Installer Settings
Normal Display Settings
Diagnostics
Valve History
These procedures can be accessed in any order. Details on each of the procedures are provided on the following
pages.
At the discretion of the manufacturer, the field technician can access all settings. To "lock out" access to diagnostic
and valve history displays and modifications to settings except hardness, day override, time of regeneration and
time of day by anyone but the manufacturer, press ▼, NEXT, ▲, CLOCK in sequence after settings are made. To
"unlock", so other displays can be viewed and changes can be made, press ▼, NEXT, ▲, and CLOCK in sequence.
When in operation normal user displays such as time of day, gallons remaining or days remaining before
regeneration, current flow rate or total gallons used are shown. When stepping through a procedure, if no buttons
are pressed within five minutes the display returns to a normal user display. Any changes made prior to the five
minute time out are incorporated.
To quickly exit Installer Display Settings, Diagnostics or Valve History press CLOCK. Any changes made prior to the
exit are incorporated.
Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return
to the preset regeneration procedure. It is possible to do a double regeneration if the control valve is set to
"NORMAL" or "NORMAL + on 0" in OEM System Setup. To do a double regeneration:
Press the "REGEN" button once. REGEN TODAY will flash on the display.
Press and hold the "REGEN" button for three seconds until the valve regeneration initiates.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset
regeneration time.