9 Cleaning and Maintenance

9.1 Cleaning

X4 ATOM components require occasional cleaning to prevent the buildup of dust, dirt,
and smoke fluid residue. Pay special attention to the air vents (on PSU and heads), and
front lens. Failure to keep the PSU and heads clean will significantly reduce light output
and may cause damage. Regular cleaning will ensure the maximum performance and
reliable operation.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended to
clean the lens.
The cleaning schedule depends on the operating environment. The intervals below are
suggestions from our experience with typical installations. Adjust as necessary.
Location
Lens
Fan and air vents

9.2 Fuse replacement

Disconnect the PSU from AC mains power before replacing the fuse.
If the PSU fails to power up when connected to a known-good source of AC power,
replace the main fuse. The fuse is located in a panel-mounted holder next to the power
switch.
Always disconnect the PSU from the mains supply to change the fuse and use only the
5 x 20 mm micro-fuse listed below for your PSU.
 X4 ATOM PSU 6: T5A
 X4 ATOM PSU 12: T10A
The X4 ATOM head does not have a user-replaceable fuse.
X4 Atom User Manual (v.0.3)
German Light Products GmbH
Disconnect the PSU from AC mains power before performing any
maintenance. Allow lighting heads to cool for at least 15 minutes.
Never use alcohol or solvents to clean the lens! Never let optical
parts come into contact with oil, grease, alcohol or similar solvents.
Never touch lens with bare fingers.
Before running the fixture wait until all parts are dry.
Interval
Method
weekly
soft brush /lint-free cloth
monthly
vacuum cleaner, airbrush, etc.
WWW.GLP.DE