Secondary Attachment
Whenever the X4 ATOM is suspended above
ground, a safety cable must be used to prevent
injury in case the primary attachment fails. The
head has a dedicated point for attaching a safety
cable at the back. The attachment point swivels in
and out as shown.
For safe and proper fastening, the safety cable
must comply with BGI 810-3 (EN 60598-2-17
Section 17.6.6) and be capable of bearing a static
suspended load that is ten times the weight of the
fixture and all installed accessories.
When suspending multiple heads from a single clamp or other primary attachment,
secure each head with its own safety cable.

3.2 PSU Installation

The X4 ATOM PSU can be suspended with a rigging clamp or placed in a rack or on a
level surface. It has an IP 22 rating and must be installed in a dry location.
When placed on a level surface or inside a rack, additional securing is usually not
required. Provide at least 10 cm (4 in.) clearance on each side for ventilation. Ensure
that the air vents on either side are not blocked.
If using a rigging clamp to hang the X4 ATOM PSU, the clamp can be fastened to the
PSU using an omega bracket or bolted directly to the unit with an M10 x 11 mm bolt.
NOTE: Never use a bolt longer than 11 mm as this may damage the device.
Whenever suspended above ground, a
safety cable must be used to prevent injury
in case the primary attachment fails. Pass
the
safety
cable
attachment point shown to right.
For safe and proper fastening, the safety
cable must comply with BGI 810-3 (EN
60598-2-17
Section
capable of bearing a static suspended
load that is ten times the weight of the
fixture and all installed accessories.
X4 Atom User Manual (v.0.3)
German Light Products GmbH
through
a
safety
17.6.6) and
be
WWW.GLP.DE
safety attachment point
2 safety attachment
points
11