Thank you for buying a SAUTER force gauge. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
„Sensor Inside" means the measuring cell is inside the
housing.
Included in delivery
1.
-
SAUTER FH incl. rechargeable battery
-
Carrying Case
-
Charger
-
Standard Attachments as shown below,
5 pcs M3 x 8 screws
Pilot lamp
Force Sensor
RS-232 port
FH_SI-BA-e-1317
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@sauter.eu
Instruction Manual
FH
FH-S Digitálny silomer(SK)
Power plug
Reset button
Display
Tel: +49-[0]7433- 9933-199
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Sensor
Inside
Important annotation:
By pressing the RESET key (on the right side of housing,
see illustration on the left), individual settings and
memorised values can be re-set or erased, in example for
a new start of the instrument after an operating error.
Data in mm
Working Conditions
2.
10°C to 30°C / 15% up to 80% humidity
Electrical Power Supply
3.
Either by rechargeable battery or current power supply
Current power supply:
-
Connection by power adapter
-
Rechargeable
simultaneously
Rechargeable battery pack for mobile applications:
-
Type: Ni 8.4V / 600 mAh
-
Charging time: approx. 1 hour
batteries
are
charged
1

Advertisement

loading

Summary of Contents for sauter FH-S

  • Page 1 By pressing the RESET key (on the right side of housing, see illustration on the left), individual settings and Thank you for buying a SAUTER force gauge. We hope memorised values can be re-set or erased, in example for you are pleased with your high quality force gauge with its a new start of the instrument after an operating error.
  • Page 2: Technical Data

    Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.kern-sohn.com Instruction Manual SET: Technical Data 1 x Press: Upper Limit [HidT / Hi Lt]. To Accuracy: ± 0,5 % of Capacity (measuring range) change press: ▲ or ▼ (see section Data Sampling Rate: 2.000 Hz...
  • Page 3: Average-Mode

    Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.kern-sohn.com Instruction Manual PEAK: Peak-Hold Function (Peak Mode) Please press: Three functions available: Track mode (continuous measurement) Auto-Peak-Hold-Function (Auto-Peak Mode) Peak mode (capture of maximum values)
  • Page 4: Output Protocol

    Newton is the selected unit described guidelines. Varying areas of application/ planned ||-----| use must be approved by SAUTER in writing. |____> the other 6 places describe the measured value as ASCII-Signs Guarantee |_______>...
  • Page 5: Ce Declaration Of Conformity

    Always make sure that there are no living beings or materials below the load that could be injured or damaged. The hanging electronic instruments from the SAUTER instrument are only suitable for hand-held use or use in a test stand. They are not suitable for hanging from a mechanical hook, e.g.
  • Page 6 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.kern-sohn.com Instruction Manual finished FH Adjustment Procedure 1 Start the Press ON/OFF The green instrument light is on 2 Enter the Directly after pressing The lower...