Download Print this page
sauter FH-M Instruction Manual

sauter FH-M Instruction Manual

Force gauge

Advertisement

Quick Links

Thank you for buying a SAUTER force gauge. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
„Sensor Outside" means the cell is outside the body.
1.
Included in Delivery
-
SAUTER FH, incl. rechargeable battery
-
Carrying Case
-
Charger
-
5 pcs. M3x 8 screws
Pilot lamp
4-pin Sensor
Force sensor
bushing
Force sensor,
RS 232 port
M6- thread
FH_SO-BA-e-1217
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Instruction Manual
FH
FH-M DIGITALNY SILOMER(SK)
Set
LCD
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www. kern-sohn.com
Important annotation:
By pressing the RESET key (on the right side of housing,
see illustration on the left), individual settings and
memorised values can be re-set or erased, in example for
a new start of the instrument after an operating error.
Data in mm
Length of cable between display and sensor: 2500 mm
Measurement Terms:
Track
= continuous measurement
Peak
= Capture of the maximum value
Dimensions of Sensors (from FH200k on inquiry)
2. Working Conditions
10°C to 30°C / 15% up to 80% humidity
Sensor
Outside
1

Advertisement

loading

Summary of Contents for sauter FH-M

  • Page 1 Thank you for buying a SAUTER force gauge. We hope a new start of the instrument after an operating error. you are pleased with your high quality force gauge with its big functional range.
  • Page 2: Electrical Power Supply

    Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www. kern-sohn.com Instruction Manual Electrical Power Supply Press short: Select unit: N, kg or lb Press for 2 sec.: Display return Either by rechargeable battery or current power supply...
  • Page 3 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www. kern-sohn.com Instruction Manual HoldT 1 x Press: Data Transfer [rS232] to PC To set these limit values, please see the SET Menu in section „Operating keys“.
  • Page 4: Average-Mode

    The measured value is requested by the PC by the ASCII described guidelines. Varying areas of application/ Sign “9”. planned use must be approved by SAUTER in writing. The measured value that comes from the instrument has Guarantee this format: The guarantee is not valid following e.g.
  • Page 5: Ce Declaration Of Conformity

    Always make sure that there are no living beings or materials below the load that could be injured or damaged. The hanging electronic instruments from the SAUTER instrument are only suitable for hand-held use or use in a test stand.
  • Page 6 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www. kern-sohn.com Instruction Manual FH Adjustment Procedure 1 Start the Press ON/OFF The green instrument light is on 2 Enter the Directly after pressing The lower...