Heating program options
Cylinder
If the program CYLINDER is choosen the shunt motor will regulate the shunt valve to maintain a
constant temperature to the flow getting it´s reference from the flow sensor. This is a very simple
way to control the temperature going to a remote cylinder where there is no possibility to connect
a sensor measuring the actual cylinder temperaure.
The active sensors in this set up is the flow sensor.
It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi-
red amount of
on two different times each individual weekday.
°C
Recommended to use when: The cylinder is very remote without possibility to connect a sensor.
Cylinder 2
If the program CYLINDER 2 is choosen the shunt motor will regulate the shunt valve to maintain
a set temperature in the cylinder. The cylinder sensor is connected on port G17 on the expansion
board.
The active sensors in this set up is the flow sensor and a sensor in the cylinder.
It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi-
red amount of
on two different times each individual weekday.
°C
Recommended to use when: Always when a cylinder is used where a sensor can be wired back
to the boiler.
Hydraulic schematics
For hydraulic references please see the full manual for the Komplett III.