Effecta Komplett III 25kW Quick Start Manual page 16

Comissioning guide

Advertisement

Program setup - temperature set
Temperature set
Press OPERATION and then open TEMPERATURE SET
menu.
In the temperature set menu you will set the desired stop
and start temperature of the burners on/off to heat the
water volume within the boiler. Our recommendation is to
have on at 65
°C
These temperatures is not at all the same or in commu-
nication with the heating circuits used to heat the house.
It is only the internal temperature within the boiler body.
Program setup - effect output
Effect output
Press OPERATION and then open the INSTALLATION
menu.
Scroll down to Effect high speed and set the boilers high
speed output at the desired effect. Never use a higher
output than the rating of the product!
If the boiler also will be used with a low power output the
Effect low speed needs to be set. We recommend it to be
50% of the boilers maximum rated output.
Never use a higher output than the maximum rated output of the product!
16
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
and off at 75
°C.
Operation settings
Burner
Fan
Feeder settings
Temperature set
Information
Service
Installation
Temperature set
Boiler temp G1
Stop temp.
Start temp.
Operation settings
Burner
Fan
Feeder settings
Temperature set
Information
Service
Installation
Installation
Advanced
Fill feeder
Effect high speed
Effect low speed
Testblow start
Phase out
Fan pre oper.
Fan low pre oper.
Off
50°C
80°C
70°C
Off
>
No
20kW
0kW
0s
10s
40%
50%